Products
Toranomy
Toranomy
Facebook
Twitter

Products



Air-cooled rooftop units

Rooftop units are the most efficient solution for the air-conditioning of spaces formed of a single volume. The LENNOX units belong to a high efficiency class due to the endowment with multiscroll compressors and usage of the R410A refrigerant. Power range:   BALTIC: 20 – 85 kW ; 3,600 – 19,000 m3/h FLEXAIR: 84 – 223 kW ; 12,000 – 43,000 m3/h Versions: cooling only heat pump cooling only and gas module or hot water heating battery dual heat pump and gas module unit Following versions are availabl...

Air-cooled chillers

Power range: ECOLEAN: 9 – 20 kW ; R407C ECOLEAN: 20 – 200 kW ; R410A NEOSYS: 200 – 1000 kW ; R410A Versions: cooling only heat pump up to 500 kW available high pressure axial fans; available at the ECOLEAN models available low noise and super low noise ECOLEAN: 20 – 200 kW with hydraulic module (single or double circulation pump; expansion vessel; safety valve; filter for impurities) available up to 600 kW with hydronic module (hydraulic module + buffer tank) available at the ECOLEAN models sc...

Water-cooled rooftop units

Water-cooled rooftop units are rooftops with heat pump operation, with the condenser connected to a water loop. The LENNOX rooftop units are the most efficient solution for the air-conditioning of spaces formed of a single volume. Power range:   BALTIC: 47 – 85 kW ; 6,500 – 14,200 m3/h FLEXY: 85 – 196 kW ; 12,000 – 35,000 m3/h Versions: heat pump dual heat pump and gas module unit scroll compressors and R410A refrigerant Versions with centrifugal or axial fan for the air exhaust are available. Possib...

Water-cooled and split chillers

Plage de puissance: HYDROLEAN: 20 – 165 kW ; R407C MWC: 180 – 720 kW ; R410A MRC: 160 – 615 kW ; R410A Versions: refroidissement seulement pompe à chaleur compresseurs scroll Options: contrôle de la pompe de circulation récupération de la chaleur partielle interface de communication contrôle à distance   ...

Ceiling air handling units

Range: MINIAIR: 1.040 – 6.450 m3/h MINIAIR+: 100 – 6.000 m3/h ; with heat recovery MINIAIR+BP: 100 – 5.500 m3/h ; with heat recovery and by-pass Possible configurations and equipments: heating & cooling battery electric battery variable speed fans G4, F6, F7 and F8 air filters control flaps noise damper vertical installation (MINIAIR+ ; MINIAIR+BP) multiple wall controls and automation ...

Air handling units

Range: 1.000 – 100.000 m3/h Possible configurations: in line superposed side by side outdoor Possible equipments: static heat recovery rotary heat recovery cooling battery heating battery direct expansion cooling battery 1, 2-speed fans and variable speed (plug fan) box-type, bag, HEPA, activated carbon air filters ...

INNOVA close control units

Power range: INNOVA: 6 – 128 kW ; R410A INNOVA ENERGY INVERTER: 3 – 63 kW ; R410A Versions: air-cooled split system water-cooled Configurations: top suction / discharge below front suction / discharge above top suction / front discharge Options: humidity control communication interface water leakage detection smoke detector flame sensor G4, G5 air filters condensate pump variabile speed condenser fan low noise condenser ...

DNOVA close control units

Power range: 2.5 – 26 kW ; R410A Versions: air-cooled split system water-cooled Configurations: wall mounted; indoor unit wall mounted; outdoor unit ceiling mounted with outdoor unit in split system top suction / discharge below front suction / discharge above top suction / front discharge Options: free cooling communication interface G3, G4 air filters ...

NEOSTAR dry coolers

Power range: 20 – 870 kW ...

MXW axial fan condensers

Power range: 50 – 1660 kW ...

ALLEGRA Cabinet and no encasing fan coil units

Range: 0.59 – 6.74 kW ; 105 – 1,500 m3/h Models: cabinet with bottom suction cabinet with front suction vertical no encasing horizontal no encasing Configurations: with 2 or 4 pipes EC fan 2 or 3-way valves electrostatic air filter condensate pump wall control ...

COMFAIR HH/HV High pressure fan coil and no encasing units

COMFAIR HH/HV High pressure fan coil and no encasing units Range: 2.8 – 61 kW ; 840 – 8,000 m3/h Models: horizontal mounting vertical mounting Configurations: with 2 or 4 pipes 2 or 3-way valves on/off, 3 points, 0-10V condensate pump wall control ...

ARMONIA / ARMONIA EC water cassettes

Range: 1.3 – 11 kW ; 310 – 1,820 m3/h Models: standard version EC version 600 x 600 mm 800 x 800 mm Configurations: with 2 or 4 pipes 2 or 3-way valves ABS air diffuser / metallic diffuser wall control infrared remote control ...

CONDAIR / CONDAIR EC water cassettes with Coanda effect

Range: 0.8 – 5.1 kW ; 182 – 750 m3/h Models: standard version EC version Configurations: with 2 or 4 pipes 2 or 3-way valves on/off, 3 points, 0-10V wall control ...

COMFAIR HD High wall fan coil units

Range: 2 – 4.4 kW ; 440 – 860 m3/h Configurations: with 2 pipes 2 or 3-way valves infrared remote control ...

AXIL / EQUITHERM air heaters and destratifier fans

Range: 12 – 105 kW Models: AXIL – hot water air heater (120°C; 16 bar) AXIL F – chilled water AXIL Z – electrical air heater AXIL V – air heater with superheated water or steam (210°C; 20 bar) EQUITHERM – destratifier fan Configurations: 1, 2 or 5-speed fan multidirectional diffuser conic diffuser fresh air intakes air filter ...

Water-cooled heat pumps

Heat pumps with condenser connected to a water loop. Power range: 4 – 20 kW Versions: cooling only heat pump Options: electrical battery hot water battery multiple ways of connecting to the piping ...

FLATAIR & COMPACTAIR

Air-conditioning units, air cooled, indoor, horizontal or vertical mounting Power range: FLATAIR: 10 – 28 kW COMPACT: 20 – 100 kW Versions: horizontal mounting - FLATAIR vertical mounting - COMPACTAIR mono-block, split, dual split scroll compressors Options: electric heating battery hot water heating battery extractor fan fresh air free cooling communication interface remote control ...

AIRCOOLAIR

Power range: 19 – 134 kW Versions: monosplit dual split scroll compressors Options: electric heating battery hot water heating battery extractor fan fresh air free cooling EU4, EU7 air filter communication interface remote control ...

ADALINK II

monitoring of up to 16 LENNOX units plug & play system it uses Internet Explorer, Chrome very easy to use possibility of elaborating a unit operation program possibility of remote connection via RTC Modem, Ethernet ...

LennoxVision

it can monitor un unlimited number of LENNOX units and other manufacturers dedicated hardware system with preinstalled software possibility of sending alert messages via SMS or E-mail possibility of elaborating a unit operation program possibility to communicate with other BMS systems possibility to remote connection via ADSL Modem ...

Copyright © 2012 | All rights reserved. Using this website, you agree with our terms and conditions.