Air-cooled rooftop units
Rooftop units are the most efficient solution for the air-conditioning of spaces formed of a single volume. The LENNOX units belong to a high efficiency class due to the endowment with multiscroll compressors and usage of the R410A refrigerant.
Power range:
BALTIC: 20 – 85 kW ; 3,600 – 19,000 m3/h
FLEXAIR: 84 – 223 kW ; 12,000 – 43,000 m3/h
Versions:
cooling only
heat pump
cooling only and gas module or hot water heating battery
dual heat pump and gas module unit
Following versions are availabl...
|
![]() |
Air-cooled chillers
Power range:
ECOLEAN: 9 – 20 kW ; R407C
ECOLEAN: 20 – 200 kW ; R410A
NEOSYS: 200 – 1000 kW ; R410A
Versions:
cooling only
heat pump up to 500 kW
available high pressure axial fans; available at the ECOLEAN models
available low noise and super low noise ECOLEAN: 20 – 200 kW
with hydraulic module (single or double circulation pump; expansion vessel; safety valve; filter for impurities) available up to 600 kW
with hydronic module (hydraulic module + buffer tank) available at the ECOLEAN models
sc...
|
![]() |
Water-cooled rooftop units
Water-cooled rooftop units are rooftops with heat pump operation, with the condenser connected to a water loop. The LENNOX rooftop units are the most efficient solution for the air-conditioning of spaces formed of a single volume.
Power range:
BALTIC: 47 – 85 kW ; 6,500 – 14,200 m3/h
FLEXY: 85 – 196 kW ; 12,000 – 35,000 m3/h
Versions:
heat pump
dual heat pump and gas module unit
scroll compressors and R410A refrigerant
Versions with centrifugal or axial fan for the air exhaust are available.
Possib...
|
![]() |
Water-cooled and split chillers
Plage de puissance:
HYDROLEAN: 20 – 165 kW ; R407C
MWC: 180 – 720 kW ; R410A
MRC: 160 – 615 kW ; R410A
Versions:
refroidissement seulement
pompe à chaleur
compresseurs scroll
Options:
contrôle de la pompe de circulation
récupération de la chaleur partielle
interface de communication
contrôle à distance
...
|
![]() |
Ceiling air handling units
Range:
MINIAIR: 1.040 – 6.450 m3/h
MINIAIR+: 100 – 6.000 m3/h ; with heat recovery
MINIAIR+BP: 100 – 5.500 m3/h ; with heat recovery and by-pass
Possible configurations and equipments:
heating & cooling battery
electric battery
variable speed fans
G4, F6, F7 and F8 air filters
control flaps
noise damper
vertical installation (MINIAIR+ ; MINIAIR+BP)
multiple wall controls and automation
...
|
![]() |
Air handling units
Range:
1.000 – 100.000 m3/h
Possible configurations:
in line
superposed
side by side
outdoor
Possible equipments:
static heat recovery
rotary heat recovery
cooling battery
heating battery
direct expansion cooling battery
1, 2-speed fans and variable speed (plug fan)
box-type, bag, HEPA, activated carbon air filters
...
|
![]() |
INNOVA close control units
Power range:
INNOVA: 6 – 128 kW ; R410A
INNOVA ENERGY INVERTER: 3 – 63 kW ; R410A
Versions:
air-cooled split system
water-cooled
Configurations:
top suction / discharge below
front suction / discharge above
top suction / front discharge
Options:
humidity control
communication interface
water leakage detection
smoke detector
flame sensor
G4, G5 air filters
condensate pump
variabile speed condenser fan
low noise condenser
...
|
![]() |
DNOVA close control units
Power range:
2.5 – 26 kW ; R410A
Versions:
air-cooled split system
water-cooled
Configurations:
wall mounted; indoor unit
wall mounted; outdoor unit
ceiling mounted with outdoor unit in split system
top suction / discharge below
front suction / discharge above
top suction / front discharge
Options:
free cooling
communication interface
G3, G4 air filters
...
|
![]() |
NEOSTAR dry coolers
Power range:
20 – 870 kW
...
|
![]() |
MXW axial fan condensers
Power range:
50 – 1660 kW
...
|
![]() |
ALLEGRA Cabinet and no encasing fan coil units
Range:
0.59 – 6.74 kW ; 105 – 1,500 m3/h
Models:
cabinet with bottom suction
cabinet with front suction
vertical no encasing
horizontal no encasing
Configurations:
with 2 or 4 pipes
EC fan
2 or 3-way valves
electrostatic air filter
condensate pump
wall control
...
|
![]() |
COMFAIR HH/HV High pressure fan coil and no encasing units
COMFAIR HH/HV High pressure fan coil and no encasing units
Range:
2.8 – 61 kW ; 840 – 8,000 m3/h
Models:
horizontal mounting
vertical mounting
Configurations:
with 2 or 4 pipes
2 or 3-way valves on/off, 3 points, 0-10V
condensate pump
wall control
...
|
![]() |
ARMONIA / ARMONIA EC water cassettes
Range:
1.3 – 11 kW ; 310 – 1,820 m3/h
Models:
standard version
EC version
600 x 600 mm
800 x 800 mm
Configurations:
with 2 or 4 pipes
2 or 3-way valves
ABS air diffuser / metallic diffuser
wall control
infrared remote control
...
|
![]() |
CONDAIR / CONDAIR EC water cassettes with Coanda effect
Range:
0.8 – 5.1 kW ; 182 – 750 m3/h
Models:
standard version
EC version
Configurations:
with 2 or 4 pipes
2 or 3-way valves on/off, 3 points, 0-10V
wall control
...
|
![]() |
COMFAIR HD High wall fan coil units
Range:
2 – 4.4 kW ; 440 – 860 m3/h
Configurations:
with 2 pipes
2 or 3-way valves
infrared remote control
...
|
![]() |
AXIL / EQUITHERM air heaters and destratifier fans
Range:
12 – 105 kW
Models:
AXIL – hot water air heater (120°C; 16 bar)
AXIL F – chilled water
AXIL Z – electrical air heater
AXIL V – air heater with superheated water or steam (210°C; 20 bar)
EQUITHERM – destratifier fan
Configurations:
1, 2 or 5-speed fan
multidirectional diffuser
conic diffuser
fresh air intakes
air filter
...
|
![]() |
Water-cooled heat pumps
Heat pumps with condenser connected to a water loop.
Power range:
4 – 20 kW
Versions:
cooling only
heat pump
Options:
electrical battery
hot water battery
multiple ways of connecting to the piping
...
|
![]() |
FLATAIR & COMPACTAIR
Air-conditioning units, air cooled, indoor, horizontal or vertical mounting
Power range:
FLATAIR: 10 – 28 kW
COMPACT: 20 – 100 kW
Versions:
horizontal mounting - FLATAIR
vertical mounting - COMPACTAIR
mono-block, split, dual split
scroll compressors
Options:
electric heating battery
hot water heating battery
extractor fan
fresh air
free cooling
communication interface
remote control
...
|
![]() |
AIRCOOLAIR
Power range:
19 – 134 kW
Versions:
monosplit
dual split
scroll compressors
Options:
electric heating battery
hot water heating battery
extractor fan
fresh air
free cooling
EU4, EU7 air filter
communication interface
remote control
...
|
![]() |
ADALINK II
monitoring of up to 16 LENNOX units
plug & play system
it uses Internet Explorer, Chrome
very easy to use
possibility of elaborating a unit operation program
possibility of remote connection via RTC Modem, Ethernet
...
|
![]() |
LennoxVision
it can monitor un unlimited number of LENNOX units and other manufacturers
dedicated hardware system with preinstalled software
possibility of sending alert messages via SMS or E-mail
possibility of elaborating a unit operation program
possibility to communicate with other BMS systems
possibility to remote connection via ADSL Modem
...
|